If you’ve ever opened an electronic device—say, a router, a desktop computer’s internal power section, or a industrial sensor array—chances are you’ve run into an open frame switching power supply (OFP SWPS). As a supplier of these units for the last seven years, I’ve spent countless hours walking engineers, design teams, and even fellow supply chain folks through exactly how they stay cool without any fancy fans or liquid cooling. A lot of people first ask: if there’s no forced air blowing, how do you keep components like MOSFETs, inductors, and rectifiers from overheating and failing? The answer boils down to natural convection, a principle that’s been around since people first noticed hot air rises—yes, really. But to get it right for open frame power supplies, it’s not just “let heat rise”; it’s a science that balances component placement, airflow paths, and the unique shape of the open frame itself. Let’s break this down like I do with a new engineer walking through a design check. Open Frame Switching Power Supply

First, let’s start with the basics: what natural convection actually is, for those who might not work with thermal dynamics every day. Natural convection relies on the fact that air expands when it’s warm, which makes it less dense than the cooler, denser air around it. Warm air rises, and cooler air sinks, creating a continuous loop that carries heat away from the component it touches. Unlike forced convection (which uses fans to push air), natural convection doesn’t require extra power or moving parts—perfect for open frame supplies, where space is tight and reliability is non-negotiable. A closed power supply might have a fan to pull air through its metal enclosure, but open frame units are just a bare PCB mounted to a frame (usually aluminum or plastic), so there’s no case blocking airflow. That open design is the key to making natural convection work, but only if you engineer for it intentionally.
When a switching power supply is working, it generates heat from two main sources: switching losses (from the MOSFETs turning on and off thousands of times per second) and conduction losses (from current flowing through resistive components like inductors and transformers). Those losses add up, and if they’re not moved away from the PCB and components, the junction temperature inside the parts can climb high enough to reduce component lifespan (most semiconductors degrade 50% faster for every 10°C rise above their rated temperature) or cause immediate failure. That’s where natural convection comes in. For our open frame units, every component is arranged to make that rising hot air can escape freely, and cool air can flow in to replace it.
Let’s talk about component placement, because this is where a lot of suppliers cut corners, but where we’ve refined our process over the years. On a standard open frame power supply PCB, the biggest heat producers get placed where the rising hot air will carry their heat away first, not stuck in a corner with no path out. For example, the primary MOSFET and the main transformer—two of the top heat generators in a switching power supply—go near the top edge of the PCB. Why? Hot air rises, so when those parts heat up, the air around them warms, expands, and moves upward, carrying heat away before it accumulates on the rest of the board. If we flipped that and put the big heat producers at the bottom, the rising hot air would get trapped under the upper components, creating a hot spot that could damage a nearby electrolytic capacitor (which hate prolonged heat exposure, making them one of the most common failure points in power supplies).
We also make sure there’s unobstructed “air channels” along the sides of the open frame. The frame itself is usually an extruded aluminum piece that acts as a heat sink, right? Aluminum is a great thermal conductor, so it picks up heat from the PCB and components, then radiates it out into the surrounding air. But if we place the PCB too close to the frame’s edges, or if we add extra components that block the space between the PCB and the frame, that air channel gets restricted, and natural convection can’t circulate as well. I once worked with a team that designed an open frame supply where they crammed a small filter capacitor right next to the transformer, and that capacitor blocked 40% of the air channel along the top edge. The unit ran 15°C hotter than our benchmark, and when we tested its lifespan, it failed at 20% less than the rated 50,000 hours. We fixed that by moving the capacitor to the side edge of the PCB, where it didn’t block the rising air flow, and the temperature dropped back to normal.
Another key part of natural convection for open frame power supplies is calculating the “temperature difference” between the hot air near the components and the ambient air around the unit. That difference drives the speed of the convection current—bigger difference means faster air flow, more heat carried away. But we can’t just push for a huge temperature difference, because that would mean higher component temperatures, which hurt reliability. So we design to a specific thermal resistance target: the amount of heat that can be transferred from the component junction to the ambient air via convection. For open frame units, we target a thermal resistance (R_th) of around 10–15°C per watt of heat generated, depending on the power rating. For a 12V, 10A open frame supply (120 watts total), that means we can’t let the heat generation exceed, say, 12 watts (since 12W x 12°C/W = 144°C, which is at the upper limit for most power components), and we size the frame and component placement to keep the actual temperature below that.
We also account for “orientation” of the open frame supply, which is a big one people miss. Natural convection works differently if the unit is mounted horizontally (with the PCB flat, top edge up) versus vertically (mounted so the PCB stands, like a wall module). When a supply is horizontal, the rising air has a clear path straight up, so convection is more efficient—we can handle up to 15% more heat output in that orientation. When it’s vertical, the air has to flow up along the sides of the PCB and frame, which is slightly slower, so we adjust component placement and thermal design to compensate. A few years back, we had a customer who wanted our 120W open frame supply mounted vertically in a industrial control panel, where space only allowed vertical mounting. We had to tweak the transformer’s heat sink to extend an extra 5mm along the top edge to create a wider air channel, which let the unit dissipate the same amount of heat without exceeding temperature limits. The customer tested it for six months, and they reported no overheating issues, which is the kind of result that makes all the late nights tweaking designs worth it.
Wait, let’s also clear up a common myth: natural convection doesn’t mean “no air flow at all.” Ambient air in any workspace or enclosure is always moving a little—from HVAC drafts, from other nearby electronics, even from small temperature fluctuations around the unit. We actually leverage that passive air movement, which is sometimes called “free convection” (as opposed to forced, but not purely static air). For open frame supplies, the open design means there’s no obstacle to that small ambient air movement, so it combines with the rising hot air from the components to create a gentle, constant flow that keeps parts cool. That’s different from a closed power supply, where the enclosure might restrict ambient air, so you need a fan to get the same flow.
Another factor is component derating, which we’ve built into every open frame supply we make as a safeguard for natural convection. Derating means we rate our components to run at lower temperatures than their maximum rated value, so even if there’s a slight unexpected increase in heat (say, from a customer operating the supply in a 40°C ambient environment instead of our standard 25°C test condition), there’s still headroom for natural convection to work. For example, our main switching MOSFETs have a maximum junction temperature of 150°C, but we design them to run at a maximum of 105°C under normal operation, which leaves a 45°C buffer if something changes. That buffer is critical because natural convection performance can vary based on installation—if a customer mounts the supply right next to another heat-generating component, the ambient temperature around our unit might be higher, so the convection loop doesn’t work as well, and that buffer keeps things safe.
I should also mention that open frame power supplies are uniquely suited for natural convection because their design is modular, unlike closed units. The frame is separate from the PCB, so we can customize the frame size and heat dissipation properties for different power levels. For low-power open frame supplies (under 50 watts), we use a small extruded aluminum frame that radiates heat directly into the air, with components spaced just enough to let air flow. For higher-power units (up to 300 watts), we add small fins to the frame—those fins increase the surface area where heat can radiate into the air, which boosts the natural convection effect. Fins are a simple addition, but they make a huge difference. I’ve seen a 200W supply go from running 65°C to 52°C just by adding 10mm tall fins to the top of the frame. That’s the kind of small, targeted change that comes from years of testing, not just textbook theory.
Now, let’s talk about what happens if natural convection doesn’t work—because even the best design can go wrong if it’s misapplied. A few years ago, we had a customer mount our 100W open frame supply in a sealed metal enclosure for a IoT gateway, instead of the open rack they had initially specified. The enclosure blocked the rising hot air, so the supply’s temperature climbed to 78°C—way above our rated 55°C max. The unit failed after three months, and when we did a thermal analysis, it turned out the closed enclosure eliminated the natural convection loop. We worked with the customer to adjust their enclosure design: they added two small vents on the top and bottom of the enclosure, which let hot air escape and cool air come in, restoring natural convection and lowering the supply’s temperature back to 58°C. That’s a perfect example of how the design depends on not just the power supply itself, but the installation environment—something we always emphasize to customers when we’re quoting units.
So to circle back: natural convection cooling for open frame switching power supplies isn’t a magic trick—it’s a combination of smart component placement, intentional air channel design, thermal material selection, and derating components to account for real-world conditions. The open frame is the foundation, because it eliminates the barriers that would block rising hot air, and the aluminum frame acts as a bridge to move heat away from the PCB into the ambient air. Every design we do goes through multiple thermal tests: we put units in environmental chambers that simulate high temperatures, low airflow, and even different mounting orientations, to make sure the natural convection system works as intended. As someone who’s been in this business long enough to see customers struggle with overheating power supplies, that testing is non-negotiable—no cutting corners on thermal design, because a power supply that fails because of overheating isn’t just a bad product, it’s a headache for the customer.

If you’re designing a system that needs a reliable, low-maintenance power supply—something that won’t fail mid-operation without a fan to clean or replace—natural convection cooled open frame units are the way to go. They’re perfect for industrial controls, IoT devices, medical equipment, and desktop electronics, where uptime is critical. We’ve helped hundreds of customers select the right open frame supply for their specific application, adjusting for power output, mounting orientation, and environmental conditions to make sure natural convection does its job. If you’re in the market for a power supply that will keep your system cool without the hassle of moving parts, let’s connect. We can walk through your requirements, run a quick thermal analysis of your application, and find the right open frame supply that fits your needs.
Enclosed Switching Power Supply References
- Incropera, F. P., DeWitt, D. P., Bergman, T. L., & Lavine, A. S. (2007). Fundamentals of Heat and Mass Transfer. Wiley.
- Texas Instruments. (2020). Thermal Design Considerations for Switching Power Supplies. Application Report SLVA999.
- International Electrotechnical Commission. (2018). IEC 62368-1: Audio/Video, Information and Communication Technology Equipment – Part 1: Safety Requirements.
Guangzhou Kaihui Electronics Co., Ltd.
Guangzhou Kaihui Electronics Co., Ltd. is one of the most professional open frame switching power supply manufacturers and suppliers in China, specialized in providing the best customized service. We warmly welcome you to buy high quality open frame switching power supply made in China here from our factory.
Address: 2F BLDG8, Standard Ind.Park, Dongchong Town, Nansha District 511453, Guangzhou, Guangdong, China
E-mail: amy@gzkaihui.com
WebSite: https://www.kaihuipowersupply.com/